Filling and closure

CLS

  • Fill level and cap
  • Compact frame

Positioned downstream of the filler and capper, it checks the fill level and the correct seating of the cap, detecting and signalling defects.

What it inspects

  • Fill level

    Level outside tolerance

    Checked on the closed product, downstream of filler and capper.

    Level outside tolerance
    Level outside tolerance
  • Cap and seating

    Presence, position, seating

    Single-optics vision: cap presence, position, seating and integrity.

    Presence, position, seating
    Presence, position, seating
  • Cap colour

    Additional module

    Detects a cap whose colour is not the expected one and sends it to rejection.

    Caps of different colours
    Caps of different colours
  • Crown cap

    Additional module

    Presence, positioning, seating and integrity of the crown cap, with fast and precise adjustments.

    Crown cap
    Crown cap
  • Stelvin cap

    Additional module

    Checks presence, position, seating and integrity; the inspection is fully parameterised.

    Stelvin cap
    Stelvin cap

Placement and capabilities

After the capper, on cap and fill level.

  1. Filler
  2. Capper
  3. Inspection
  4. Labeller
  5. Outfeed
FillerCapperLabellerOutfeedInspectionInspection
  • Single optics, industrial PC

    Single-optics vision system powered by an industrial PC.

  • Small footprint

    Compact dimensions: easy to fit into an existing line.

  • Three inspection modules

    Colour, Corona and Stelvin: each type of cap has its own inspection.

  • Rejection with REJ systems

    Paired with a rejection system, it ejects the defective item from the line.

  • Industry 4.0 and remote support

    Ethernet, OPC-UA, MQTT and Modbus; support over encrypted sessions.

Technical data

Control resolution
starting from 1.3 megapixels
Type of inspection
Monochrome
Production capacity
up to 40.000 pieces/h
Display
TFT 15.6″ FHD touch screen
Power supply
230 Vac 50-60 Hz + Earth
Absorbed power
300 W
Weight
100 Kg
Operating temperature
0 – 45 °C
Protection
according to CE

Documentation

Manual and technical documentation

Available on request for the installed product.

Request the manual

Frequently asked questions

What does CLS inspect?

CLS runs 5 inspections: fill level, cap and seating, cap colour, crown cap, stelvin cap.

What are the main specifications?

The main specifications are: control resolution starting from 1.3 megapixels, production capacity up to 40.000 pieces/h and display TFT 15.6″ FHD touch screen.